-- General information --

File name: /home/sachsenb/Development/OpenMS/src/tests/topp/FileInfo_9_input.mzML
File type: mzML

Instrument: LCQ Deca
  Mass Analyzer: Quadrupole ion trap (resolution: 0)
  Mass Analyzer: Linear ion trap (resolution: 0)

MS levels: 1, 2
Total number of peaks: 40
Number of spectra: 4

Combined Ranges (spectra + chromatograms):
  retention time: 5.10 .. 5.40 sec (0.0 min)
  mass-to-charge: 0.00 .. 18.00
  ion mobility: <none> .. <none>
  intensity: 1.00 .. 20.00

Spectrum Ranges:
  retention time: 5.10 .. 5.40 sec (0.0 min)
  mass-to-charge: 0.00 .. 18.00
  ion mobility: <none> .. <none>
  intensity: 1.00 .. 20.00

MS Level 1 Ranges:
  retention time: 5.10 .. 5.40 sec (0.0 min)
  mass-to-charge: 0.00 .. 14.00
  ion mobility: <none> .. <none>
  intensity: 1.00 .. 15.00

MS Level 2 Ranges:
  retention time: 5.20 .. 5.20 sec (0.0 min)
  mass-to-charge: 0.00 .. 18.00
  ion mobility: <none> .. <none>
  intensity: 2.00 .. 20.00

Chromatogram Ranges:
  retention time: <none> .. <none> sec (<none> min)
  mass-to-charge: <none> .. <none>
  intensity: <none> .. <none>

Number of spectra per MS level:
  level 1: 3
  level 2: 1

Peak type from metadata (or estimated from data)
  level 1: Centroid (Centroid)
  level 2: Centroid (Unknown)

Activation methods
    MS-Level 2 & CID (Collision-induced dissociation): 1

Precursor charge distribution:
  charge 2: 1x

Meta data array:
  charge array:          1 spectra
  signal to noise array: 1 spectra


-- Meta information --

Document ID:        OpenMS_document_id
Date:               2007-06-27 15:23:45

Sample:
  name:             Sample1
  organism:         
  comment:          

Instrument:
  name:             LCQ Deca
  model:            
  vendor:           
  ion source(s):    Electrospray ionisation, Fast atom bombardment
  mass analyzer(s): Quadrupole ion trap, Linear ion trap
  detector(s):      Electron multiplier, Electron multiplier

Contact person:
  first name:     William
  last name:      Pennington
  email:          wpennington@higglesworth.edu


-- Data processing information --

Note: The data is taken from the first spectrum!

Processing 1:
  software name:    ProteoWizard software
  software version: 1.0
  completion time:  0000-00-00 00:00:00
  actions:          Conversion to mzML format


-- Statistics --

Intensities:
  num. of values: 30
  mean:           8
  minimum:        1
  lower quartile: 4
  median:         8
  upper quartile: 12
  maximum:        15
  variance:       19.3103

Meta data: charge array
  num. of values: 10
  mean:           11
  minimum:        2
  lower quartile: 5
  median:         11
  upper quartile: 17
  maximum:        20
  variance:       36.6667

Meta data: signal to noise array
  num. of values: 10
  mean:           11
  minimum:        2
  lower quartile: 5
  median:         11
  upper quartile: 17
  maximum:        20
  variance:       36.6667