#include <poissonBoltzmann.h>
Static Public Attributes | |
| const int | VERBOSITY |
| Default verbosity level. | |
| const bool | PRINT_TIMING |
| Default timing verbosity. | |
| const float | SPACING |
| Default grid spacing. | |
| const float | BORDER |
| Default distance between outmost atom and border. | |
| const float | IONIC_STRENGTH |
| Default ionic strength of the solvent. | |
| const float | TEMPERATURE |
| Default temperature. | |
| const float | PROBE_RADIUS |
| Default probe radius. | |
| const float | ION_RADIUS |
| Default ionic exclusion radius. | |
| const String | BOUNDARY |
| Default boundary condition. | |
| const String | CHARGE_DISTRIBUTION |
| Default charge distribution method. | |
| const String | DIELECTRIC_SMOOTHING |
| Default method for dielectric smoothing. | |
| const float | SOLVENT_DC |
| Default solvent dielectric constant. | |
| const float | SOLUTE_DC |
| Default solute dielectric constant. | |
| const float | RMS_CRITERION |
| Default convergence criterion for RMS change. | |
| const float | MAX_CRITERION |
| Default convergence criterion for maximum change in potential. | |
| const Index | MAX_ITERATIONS |
| Default for maximum number of iterations. | |
| const Index | CHECK_AFTER_ITERATIONS |
| Default for the number of iterations between two checks for convergence. | |
These values are used by FDPB::setup methods if no options have been set.
|
|
Default distance between outmost atom and border. Default is 4.0 Angstrom.
|
|
|
Default boundary condition.
|
|
|
Default charge distribution method. Default is ChargeDistribution::uniform
|
|
|
Default for the number of iterations between two checks for convergence. Default is 10
|
|
|
Default method for dielectric smoothing. |
|
|
Default ionic exclusion radius. Default is 2.0 Angstrom
|
|
|
Default ionic strength of the solvent. Default is 0.0 mol/l
|
|
|
Default convergence criterion for maximum change in potential. Default is 1E-4 |
|
|
Default for maximum number of iterations. Default is 500. This value is inappropriate for very large grids.
|
|
|
Default timing verbosity. false - don't tell anything
|
|
|
Default probe radius. The probe radius used for the creation of the solvent excluded surface of the solute. It should be the solvent radius. Default is 1.5 Angstrom for water.
|
|
|
Default convergence criterion for RMS change. Default is 1E-5 |
|
|
Default solute dielectric constant. Default is 2.0 (good average derive from organic solvents).
|
|
|
Default solvent dielectric constant. Default is 78.0 (roughly the dielectric constant of water at 298 K)
|
|
|
Default grid spacing. Default grid spacing is 0.6 Angstrom.
|
|
|
Default temperature. Default is 298.15 K
|
|
|
Default verbosity level. 0 - shut up!
|